PROBLEMS RELATED TO IME245 : Verify the status of the LED on the IME245. The LED that indicates a fault on the board itself are only the two green leds on top-right part of the board, that signalize the presence of 12V D.C and 24V A.C for the heaters (these leds are present in TX and RX boards). All the other leds (present only on RX board) show the alarm/disqualifying status that arrives them from other technologies in the pillar (IR, MW, Doppler). These Leds in normal conditions must be in OFF. If they’re in ON verify why the relative technology has generated the alarm (follow the previous tables).
|
PROBLEMS RELATED TO BEA1224ALIEX : · Verify the LED status on the power supplier :
|
TROUBLESHOOOTING |
BEA1224ALIEX |
LED1 (Red) |
LED2 (Green) |
LED3(Green) |
LED4(Green) |
LED5(Green) |
OFF |
OK |
24V of the Secondary not present before the thermostat |
24V of the Secondary not present after the thermostat |
Defected battery fuse |
No 230V input present |
ON |
Battery polarity reversed |
OK |
OK |
OK |
OK |