SICURIT ALARMITALIA MANUALSFAMIGLIE DI PRODOTTI

PROBLEMS RELATED TO IME244 :

Verify the status of the LED on the IME244. The LED that indicates a fault on the board itself are only the two green leds on top-right part of the board, that signalize the presence of 12V D.C and 24V A.C for the heaters (these leds are present in TX and RX boards). All the other leds (present only on RX board) show the alarm/disqualifying status that arrives them from other technologies in the pillar (IR, MW, Doppler). These Leds in normal conditions must be in OFF. If they’re in ON verify why the relative technology has generated the alarm (follow the previous tables).

 

PROBLEMS RELATED TO BEA1224ALIEX :

· Verify the LED status on the power supplier :

 

 

 

INTRODUCTION

COMPONENTS

ALIGNMENT / TESTS

SUGGESTIONS

TROUBLESHOOOTING

ASSOCIATIONS

BEA1224ALIEX

LED1 (Red)

LED2 (Green)

LED3(Green)

LED4(Green)

LED5(Green)

OFF

OK

24V of the Secondary not present before the thermostat

24V of the Secondary not present after the thermostat

Defected battery fuse

No 230V input present

ON

Battery polarity reversed

OK

OK

OK

OK