SICURIT ALARMITALIA MANUALSFAMIGLIE DI PRODOTTI

CABLINGS TO BE MADE FOR A CORRECT CMH9000PER INSTALLATION :

WHEN CABLINGS AND CONFIGURATION ARE MADE VERIFY THE LEDS STATUS :

INTRODUCTION

INSTALLATION & TROUBLESHOOTING

MENU CONFIGURATION

ASSOCIATIONS

SUPPLY

DIPSWITCH

LAN

COM PORTS

INPUTS

OUTPUTS

V- : ref. 12V

V+ : positive 12V

ON : 1,3,5

OFF: 2,4,6,7,8

CMH8P/FENSOFTHP trough  switch.

Peridect config. software : switch o direct connection to PC with virtual COM

COM0 : FENCEN (TX->RX, RX->TX)

COM1 : Not used

V- : reference

1/4 : input (double bal. 1KΩ)

C+: ref. (12V)

1/4 : output

(max 30mA)

 

 

 

 

 

 

 

LED POWER

LED STATUS

LEDS COM0

LEDS COM1

ON

OK

Fault

Noise on the serial line, verify cablings on it (normally made when H wire is on L wire)

Interferences or noises

OFF

Verify power supply 12V DC

Verify power supply, if present fault.

Verify Cablings

OK

SLOW BLINKING

/

OK

OK, with 1 sec. interval

Interferences or noises

FAST BLINKING

/

/

/

Interferences or noises