Setup parameters on transmitting microwave :
· ON/OFF : Activate or deactivate the radio signal transmission · BATTERY CONNECT : Tell to microwave that the system has a backup battery · FREQUENCY : Set the transmission frequency channel The button LOAD allows to charge a previously saved configuration (on a Text format file) |
Diagnostic parameters on transmitting microwave :
The window is divided in Three sectors : · STATUS : Show the actual status of the microwave. · SETUP : Shows how the user has configurated the microwave from the setup window · ANALOG VALUES : Shows in real time the analogic parameters of the microwave. The user has the possibility to save periodically the status of the microwave on a txt file, trough SAVE button (see manual) |
MW TX MANAGE |
STATUS |
SETUP |
ANALOG VALUES |
RESTART : microwave is restarting |
TX ON : microwave swtiched on or off |
OUTPUT VOLTAGE RANGE : 9.5V +/- 5% |
ERROR : Generic Trouble on microwave electronic |
SECOND ANTENNA : Presence of the second parabola |
1ST ANTENNA CURRENT RANGE : 25mA +/- 30% |
SUPPLY ERROR : 12V power supply out the correct range |
BATTERY CONNECT : Presence of the backup battery in the microwave |
2ND ANTENNA CURRENT RANGE : 50mA +/- 30% |
BATTERY ERROR : Low power supply on the battery |
FREQUENCY : shows the selected transmission channel |
MODULATOR SUPPLY RANGE : 9,5V +/- 5% |
OUTPUT ERROR : Wrong transmission from the output antenna |
|
SUPPLY VOLTAGE RANGE : 11V < V < 13.6V |
EXTERNAL OFF : Reset analogic input (external off) activated |
|
BATTERY VOLTAGE RANGE : Must have sufficient power to recharge the connected battery |