Setup Parameters of Receiving microwave :

SETUP PARAMETERS :  Set  special funcions of microwave (switch on/off, normal or test mode, force disqualification, battery connection etc)

· FREQUENCY : Set the frequency that the microwave must read from the transmitter I

· DELAY TIME : Set the delay time for MW calibration

· SENSITIVITY : Set the sensitivity (1/99) for MW calibration LOAD button allows to charge previously saved configuration

Diagnostic parameters on receiving microwave :

The window is divided in Three sectors :

· STATUS : Show the actual status of the microwave.

· SETUP  : Shows how the user has configurated the microwave from the setup window

· ANALOG VALUES :  Shows in real time the analogic parameters of the microwave.

The user has the possibility to save periodically the status of the microwave on a txt file, trough SAVE button (see manual). He can also store only during the alarms, to see the changes. On

bottom-left part are shown delay time and sensitivity set by user

DESCRIPTION

INSTALLATION

MW TX MANAGE

MW RX MANAGE

STATUS

SETUP

ANALOG VALUES

RESTART : microwave is restarting

RX OFF : microwave swtiched on or off

FREQUENCY : Channel 1 : 900Hz +/5%,  Channel 2 : 1150Hz +/- 5%, Channel 3 : 1500Hz +/- 5%, Channel 4 : 2400Hz +/- 5%

ERROR :  Generic Trouble on microwave electronic

TEST  : Microwave is set in test mode, with AGC functions blocked

INPUT VOLTAGE : 0,7V +/- 5%

SUPPLY ERROR : 12V power supply out the correct range

LOW SENSIVITY : Microwave forced to work in low sensitivity mode

REFERENCE VOLTAGE : 1,7V +/- 5%

BATTERY ERROR : Low power supply on the battery

BALANCED INPUT : shows that the user has activate the hardware input for forcing the sensitivy reduction

ANALOG SUPPLY VOLTAGE :  ca SUPPLY VOLTAGE- 5%

DISQUALIFICATION : Microwave works in low sensitivity mode, through sense hardware input

UP-DOWN TEST : shows that up-down test function is active

SUPPLY VOLTAGE RANGE :  11V < V < 13.6V

INTERFERENCE : Microwave have some interferences from external sources. Verify

BATTERY CONNECT : show that the user has set up a battery connection

BATTERY VOLTAGE RANGE : Must have sufficient power to recharge the connected battery

WRONG FREQ : Transmitter and receiver microwave have different channels set.

 

AGC : from 0% to 99%, top working range after alignment  15%<AGC<25%

ALARM : The microwave has detected something crossing its

 

ALARM DELAY TIME VALUE : Last alarm delay time (> 15ms)

 

 

ALARM SENSITIVITY VALUE : Last mass % detected. 1/99% according to MW set sensitivity