At the entering into CMH9000DAVE webbrowser (to enter insert as address the default value 192.168.1.222) will be asked entering username and password

DEFAULT USERNAME : Admin

DEFAULT PASSWORD : Sicurit

INTRODUCTION

INSTALLATION & TROUBLESHOOTING

MENU CONFIGURATION

CMH8OUT

ASSOCIATIONS

MENU

PARAMETRI

OVERVIEW

There are shown the datas related to interface firmware and the status on analogic inputs and outputs of the board (Outputs open/closed, Inputs 0=standby, 1=alarm, 2=tamper)

NETWORK CONFIGURATION

IP ADDRESS : IP of the CMH9000DAVE board

GATEWAY: Network Gateway Address

SUBNET MASK : 255.255.255.0 (tipically)

 

MODE CONFIGURATION

MODE : Masterdave

BARRIERS ON COM1 : select 1/8 in base of the addreses of the MESDAVE200RS present on the RS485

SERIAL OUTPUTS MODULES : select 1/30 in base of the addreses of the CMH8OUT on the RS485 connected to COM0.

N.B : speed boudrate chosen for CMH8OUT MUST be always the same!

 

OUTPUT CONFIGURATION

Insert in the field related to the desired parameter (described in the table of the browser) the code of the output on CMH9000DAVE/CMH8OUT. In the window scrolling menu there are present the connected microwaves (selected in mode configuration); Before to change the barrier SAVE the parameters of the actual one, to not lose inserted datas.

· 1…...4                    4 outputs on CMH9000DAVE

· 11…18           8 outputs module CMH8OUT with address 1

· 21…28           8 outputs module CMH8OUT with address 2

· 301..308         8 outputs module CMH8OUT with address 30

COM0 SETUP

SPEED : 9600bps (or different, in base of what is set on CMH8OUT modules)

DATABIT : 8

PARITY : none

STOP BITS : 1

COM1 SETUP

SPEED : 4800bps

DATABIT : 9

PARITY : none

STOP BITS : 1

PASSWORD CHANGE

ACTUAL PASSWORD : actual password, to confirm the change

NEW PASSWORD : new password for browser protection

RETYPE PASSWORD : confirmation new password