· All the detectors are pre-cabled in factory and pre-addressed.

· On the fence put a sensor each fence panel, at its center. It’s important, if there’s  an horizontal bar or a tie-wire (expecially on mesh fences), to not put the detector directly on it, to prevent a cut of vibrations. It’s suggested, if it is in the middle, tu install the FENSEN10 immediately over or under it. Maximum detector sensivitiy is 3,5mt of widthness X 2,5 of Heightness.

· Fix the detector to the fence with its counter-plate and the related screws. The detector must be perfectly on the fence.

· In case of hidden version installing, the range of pole hole must be 48mm/60mm

 

FENSEN30

· All the detectors are pre-cabled in factory and pre-addressed.

· The detectors must be lodged in the dig (that could be wide 20cm and deep according to the kind of terrain). Tipically the detector grants a 1,5mt radius of detection, according to the kind of terrain. There are provided special sealed junction unit to join the underground part to the cable that will go to FENCEN

· The wider part of the detector must be placed on upper side, to have a bigger detection area.

· Typical depths and distances between the sensors are :

         - 40cm depth  every 2,5 mt under dirt

         - 10cm depth every 1,5mt under asphalt or           

          Porphiry.

· System not works under not pressed sand

 

FENSEN15

· Modules are provided pre-addressed but normally not pre-cabled.

· To install, choose the point where will be located the module and cut the bus. Then, with the provided scotchlock connectors, put in series the module with the detectors. At last put it on the fence as a FENSEN10.

· Connect the desired input or output, remembering the 2.2KOhm double balancing

 

FENCEN

· To FENCEN must be connected the following devices :

   - Sensor Line

   - RS232 Cable if the system wants to be monitored qualora si voglia monitorare il sistema

   - Cables directed from external devices to FENCEN inputs or from FENCEN outputs to a control panel

   - 12V D.C Power Supply