Verify the Sensitivity Jumper status :

Inserted Jumper : high (51%-100%)

Open Jumper : low (1% - 50%)

2

Rotate the sensitivity trimmer to change sharply the sensitivity value :

Clockwise  : sensitivity increasing 

Anticlockwise : sensitivity decreasing

3

Verify the inserting of the led jumper. (after the tests, if wanted, the user can leave it not inserted).

4

Made the detection tests with the selected sensitivity, verifying the following conditions :

1) in standby green led ON / yellow led OFF

2) in alarm green led OFF / yellow led ON The green led remains in ON until the alarm relay will close (tipically some seconds)

3) In case of cable cutting yellow led permanently ON

4) In case of short circuit on the cable (or tamper on FLEXTR/FLEXCN) flashing yellow led 5)

In case of tamper on FLCEN only the tamper relay will change its status, not the led.