HOW TO RECOGNIZE POTENTIAL TROUBLES :

 

INTRODUCTION

TROUBLESHOOTING

INSTALLATION

SETTINGS / TESTS

COMPONENTS

ASSOCIATIONS

TIPO

PROBLEMA

PROVE

GREEN LED ON FENCEN SHUT DOWN / NO LINES IN MONITOR LINE

NO BUS COMMUNICATION

· VERIFY THE CORRECT BUS CABLING

· VERIFY THAT THERE IS SET THE CORRECT ADDRESS 485 ON THE SOFTWARE

RED LED SHUT DOWN

LACK OF POWER

· CONTROL THE POWER SUPPLIER

 

THE SOFTWARE DID NOT OPEN

ERROR ON COM PORT

· VERIFY  IF CONFIG.TXT IS CORRECTLY CONFIGURED

· VERIFY, IN CASE OF USB CONVERTER USE, THAT CABLE DRIVERS ARE CORRECTLY INSTALLED.

· VERIFY , IN CASE OF IP CONVERTER USE, THAT  IP AND PORTS ARE PROPERLY CONFIGURED.

DETECTOR FAULT

DETECTOR DOES NOT CATCH

· VERIFY WITH THE SOFTWARE,  ON PDS STATUS WINDOW, IF THE SENSORS HAVE THE LABEL FAULT.

· VERIFY DETECTOR PARAMETERS

 

NOT WORKING OUTPUT

DOES NOT GIVE CORRECT OUTPUT

· VERIFY THE CORRECT ASSOCIATION BETWEEN DETECTOR AND OUTPUT

· VERIFIY THAT THE OUTPUT IS CORRECTLY CONFIGURED (THE 12V O.C COULD WORK  IN FOLLOWER OR INVERTOR MODE, ACCORDING TO USER SETTINGS)

NOT WORKING INPUT

DOES NOT GIVES ALARM (FROM SOFTWARE)

· VERIFY THE BALANCING

 

SIGNAL INTERFERENCES

TIMELINES IN MONITOR LINE WINDOW NOT GREEN AND/OR NOT STABLE

· VERIFY SYSTEM GROUNDING

· VERIFY THAT THERE ARE NOT DETECTORS WITH THE SAME ADDRESS